Energier Apollo User Manual
52
Model No.
Operating ambient
temperature range
Net weight (kg)
20 22 2520
Other Data
Temperature compensation
a)shortcut, b)over load, c)over temperature, d)AC input voltage
out of range, e)Battery voltage out of range, f)fan lock
Auxiliary output
Protection
Cooling
Dimension (mm) (max) 515 × 275 × 145
Forced fan
IP21Protection
EN60950-1, EN62109-1/-2
EMC
Safety
Standard
EN61000-6-4 , EN61000-6-2, EN61000-3-3, EN61000-3-2
CH2.0M
-4mV / ℃/cell, settable
-40℃~85℃
-20℃~60℃
CH2.0S CH3.0S CH4.0S
X2, programmable
Storage temperature range
Mechanical Data
AC charger
Solar charger
MPPT
35
40 20 30 40
60 60 60 60
100 80 90 100
Solar charger type
Nominal output voltage (VDC)
AC Charger& Solar Charger
Max PV open circuit
voltage (Voc) (VDC)
24 48
100 150
MPPT range (VDC)
Max PV short circuit current (A)
Recommended PV (W)
Rated charging
current-adjustment (A)
2000 4000 4000 4000
32~95
64~140 (150VDC absolute maximum
coldest conditions,140VDC start-up
and operating maximum)
Max charging current (A)
MPPT efficiency 99.5%
98%
AGM / GEL / LFP / flooded / lead-carbon / traction / semi-traction
Solar charger max efficiency
Battery types