1. GENERAL INFORMATION
1.1. User Manual Content
This User’s Manual contains the operating instructions, installation instructions and
specifications of the Genesys
TM
15KW and 10KW power supply series. The instructions refer
to the standard power supplies, including the built-in RS232/485 serial communication. For
information related to operation with the optional IEEE programming, refer to User’s Manual
for Power Supply IEEE/IEMD Programming Interface. For information related to operation
with the optional LAN programming, refer to the User’s Manual for Power Supply LAN
Programming Interface.
1.2. Introduction
1.2.1. General Description
Genesys
TM
power supplies are wide output range, high performance switching power
supplies. The Genesys
TM
series is power factor corrected and operates from specified AC
voltage range continuously. Output voltage and current are continuously displayed and
LED indicators show the complete operating status of the power supply. The Front panel
controls allow the user to set the output parameters, the protections levels (Over-Voltage
protection, Under-Voltage limit and Foldback) and preview the settings. The rear panel
includes the necessary connectors to control and monitor the power supply operation by
remote analog signals or by the built-in serial communication (RS232/485). GPIB
programming and Isolated-Analog programming/monitoring are optional
1.2.2. Features and Options
Constant Voltage / Constant Current with automatic crossover.
Embedded Microprocessor Controller.
Built-in RS-232/RS-485 Interface.
Voltage & Current high resolution adjustment by digital encoders.
High accuracy programming/ readback.
Last Setting Memory.
Independent Remote ON/OFF (opto-isolated) and remote Enable/Disable.
Remote sensing to compensate for voltage drop of power leads.
External Analog Programming and Monitoring standard (0-5V or 0-10V, user
selectable).
Zero stacking
No ventilation required at the top and bottom surface of the power supply.
Option IEEE-488 (GPIB) and LAN interface are SCPI compliant.
Optional Isolated Analog programming/monitoring (0-5V or 0-10V, or 4-20mA).
1.2.3. Control via the Serial Communication Port
The following parameters can be programmed via the serial communication port:
a) Output voltage setting.
b) Output current setting.
c) Output voltage measurement.
d) Output On/Off control.
e) Output current measurement.
f) Foldback protection setting
g) Over-voltage protection setting and readback.
h) Under-Voltage limits setting and readback.
i) Power-supply start up mode (last setting or safe mode).