RECORD
LEVEL
SET
~
Adjustments
Are
Accessible
From
The
Rear
Panel.
HIGH
position
7.
The
OUTPUT
and
LINE
controls
must
be
at
the
specified
level
position.
8.
Apply
a
400
Hz
signal
at
-8 dB
to
the
LINE
IN
jacks.
9.
Thread
record
test
tape
Scotch
203
on
the
unit,
then
set
the
BIAS
and
EQ/LEVEL
switch
to
HIGH
position.
10.
Place
the
unit
in
the
stereo
record
mode
with
the
MONITOR
switch
in
the
TAPE
position.
il.
While
recording
this
signal
on
the
Scotch
203
record
test
tape,
ad-
just
VR-109/209
for
a
reading
of
0
VU
on
the
VU
meters
(-8
dB
at
the
OUTPUT
jacks).
NOTE:
REC
level
VR-109/209,
108/208
and
VU
meter
calibration
VR-106/206
will
interact;
after
adjusting
REC
level,
recheck
VR-106/206
to
ascertain
that
it is
still
correct.
NORMAL
position:
12.
Thread
record
Scotch
150
tape
on
the
unit,
then
set
the
BIAS
and
EQ/LEVEL
switch
to
NORMAL
position.
13.
Repeat
step
7
and
8
above,
and
record
this
signal
on
the
tape.
14.
Adjust
VR-108/208
for
a
reading
of
0
VU
on
the
VU
meters.
15.
After
this
adjustment,
return
the
BIAS
and
EQ/LEVEL.
switch
to
HIGH
position.
LEVEL
VARIATION
CHECK
Using
TEAC
M-826A
level
meter
and
Scotch
203
test
tape,
recording
at
the
specified
level
setting
with
BIAS
control
in
HIGH
position,
the
output
Level
variations
should
not
exceed
those
shown
in
the
chart
below.
7-1/2ips:
0.5
dB
at
400
Hz
1.0
dB
at
15
kHz
3-3/4ips:
1.0
dB
at
10
kkz
Fig.
7-11
Level
Variation
Wave
Form
7-8