Annex 14 Exchanging the Coolant
1. Draining the coolant:
Open the clamp on the lower hose of the water
radiator, disconnect the hose and allow the coolant to
drain into a prepared collecting container.
Open the clamp on the lower hose of the heat
exchanger, disconnect the hose and allow the coolant
to drain into a collection container.
Open the drain plug. Allow the coolant to drain into a
collection container.
After draining reinstall and tighten the drain plug.
Tightening Torque:
30 Nm
Reconnect the lower hoses of the water radiator and
the heat exchanger. Tighten the clamps.
2. Filling up new coolant:
Fill up the cooling system with coolant according to
IM-02-02 Chapter 4 by opening the coolant filler.
Close the cover of the coolant filler.
Perform a test run according to
Chapter 4, Section 4.4.2, Page 5 of this Manual.
Check the cooling system for leaks according to
Annex 3 of this Chapter.
Allow the engine to cool down.
Check coolant level.
WARNING: Risk of scalding! The cooling system may be pressurized.
Carefully release the pressure before opening the drain plug.
CAUTION: Do not drain the coolant if its temperature is above 40°C.