EasyManuals Logo

Technify Motors CD-155 User Manual

Default Icon
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
Operation & Maintenance Manual
CD-135 / CD-155
OM-02-02
Revision no.:
Revision date:
Chapter:
Issue:
Issue date:
Page:
Content:
02-OM-04-02
4
30.07.2014
7
10
2
02.09.2015
4.4.3 FADEC-Reset (from Software 2.7 on and following)
In case of a FADEC-warning, one or both FADEC warning lamps
are flashing. If the "FADEC" test button then is pressed for at
least 2 seconds, the following possibilities will occur:
Temporary failure
The active warning lamps will extinguish if it is a LOW category
warning and a temporary, not steady, failure.
In case of a temporary failure the FADEC light will illuminate after
the ignition has been switched off and on.
Steady failure or high category failure
The active warning lamps will illuminate steady if it is a steady
failure or high category failure.
WARNING: If a FADEC-warning occurred, contact your service center! Next
flight is not permitted!
WARNING: If a FADEC-warning occurred, contact your service center! Next
flight is not permitted!

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Technify Motors CD-155 and is the answer not in the manual?

Technify Motors CD-155 Specifications

General IconGeneral
BrandTechnify Motors
ModelCD-155
CategoryEngine
LanguageEnglish

Related product manuals