Operation & Maintenance Manual
CD-135 / CD-155
OM-02-02
Revision no.:
Revision date:
Chapter:
Issue:
Issue date:
Page:
Content:
02-OM-06-02
4
30.07.2014
73
74
7
20.07.2016
12. If both firmware and mapping have been updated, a second
Form 1 will be presented when closing the first one (see
step 11).
13. After comparing the checksums you may close the FADEC
Updater.
14. Perform a „Diagnostic Reset“. Refer to Section 7 „Clearing
Diagnostic Warnings“ in Annex 10 of this Chapter.
15. Start the FADEC Service Tool.
16. Compare the CRC checksums with those found on the
Form 1(s) (see Fig. 6.63 and Fig. 6.64).
17. Disconnect the USB CAN interface from the FADEC and
your computer.
18. Engine master switch - „OFF“
19. Battery master switch - „OFF“
CAUTION: The CRC checksums presented by the FADEC Service Tool
need to match exactly with those on the Form 1(s). In case of a
mismatch contact Technify Motors GmbH immediately!
Fig. 6.65 FADEC Service Tool