Checklist
4
17.04.2015
2
2
Revision no.:
Revision date:
-
-
Engine Maintenance Checklist - After the 3rd - 6th
operating hour
Perform an engine test run
according to Chapter 4, Section 4.4.2, Page 5 of this Manual, read out the FADEC. E-mail
both the Real Time Log Files and Event Log Files to Technify Motors GmbH
(refer to Chapter 6, Annex 10 of this Manual)
Exchange the gearbox oil filter
(refer to Chapter 6, Annex 8 of this Manual)
The used gearbox oil filter should be labeled, stored in a clean container and made
available to Technify Motors GmbH on request for the complete engine life time. The
sample will be required for a later long-run analysis. The label must show the aircraft serial
number, registration number, engine serial number, operation time and date.
Check the presetting of the proportional pressure reducing valve
(refer to RM-02-02, Chapter 72-10.05 or Chapter 72-10.16).
Inspection Items Initials
FINAL INSPECTOR
in block letters
date, signature

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Technify Motors CD-155 and is the answer not in the manual?

Technify Motors CD-155 Specifications

General IconGeneral
BrandTechnify Motors
ModelCD-155
CategoryEngine
LanguageEnglish

Related product manuals