Annex 4 Engine Test Run
Check the starting behavior:
1. Start the engine according to
Chapter 4, Section 4.2, Page 2 of this Manual.
2. Warm up the engine according to
Chapter 4, Section 4.3, Page 3 of this Manual.
3. Perform the engine test run according to
Chapter 4, Section 4.4.2, Page 5 of this Manual.
4. Shut down the engine according to
Chapter 4, Section 4.7, Page 9 of this Manual.
CAUTION: Do not overheat the starter. Do not operate the starter for more
than 10 seconds. After operating the starter, let it cool down for
20 seconds. After six attempts to start the engine, let the starter
cool down for half an hour.