EasyManua.ls Logo

TechnipFMC Smith Meter microLoad.net - Table 5. MNET Board Terminal Assignments

TechnipFMC Smith Meter microLoad.net
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...

Section IV – Diagrams
Table 5. MNET Board Terminal Assignments
Connector: CN1
1COM2232Tx 485Tx-
2COM2485Tx+
3COM2232Rx 485Rx+
4COM2485Rx-
5 Common
6COM3232Tx 485Tx-
7COM3485Tx+
8COM3232Rx 485Rx+
9COM3485Rx-
10 Common
Terminal #Description232 485
Connector: CN2
1COM1232Tx 485Tx-
2COM1485Tx+
3COM1232Rx 485Rx+
4COM1485Rx-
5 Common
Terminal #Description 232485
Connector: CN3
1 RTD +
2SIG +
3SIG -
4RTD -
5 Shield
Terminal #Description
Connector: CN4
1Input (DC) #1 +
2Input (DC) #1 -
3 Input (DC) #2 +
4Input (DC) #2 -
5 Input (DC) #3 +
6Input (DC) #3 -
7 Pulse Out +
8Pulse Out -
Terminal #Description
Connector: CN5
1Meter Pulse Input/Channel A +
2Meter Pulse Input/Channel A -
3Factory Use Only - Do not connect
4Factory Use Only - Do not connect
5Shield
6Meter Pulse Input/Channel B/Metered Inj +
7Meter Pulse Input/Channel B/Metered Inj -
8Factory Use Only - Do not connect
9Factory Use Only - Do not connect
10 Shield
11 Output (DC) #1 +
12 Output (DC) #1 -
13 Output (DC) #2 +
14 Output (DC) #2 -
Terminal #Description
Connector: CN6
1Factory Cable to MACF (DC PW R +)
2Factory Cable to MACF (Common)
3Factory Cable to MACF (+12 Vdc Transmitter) power
4Factory Cable to MACF (Common)
5Factory Cable to MACF (Earth/Enclosure Gnd)
Terminal #Description
Connector: CN7
1 AC Output Common
2N.C.
3Output (AC) #6
4Output (AC) #5
5Output (AC) #4
6Output (AC) #3
Terminal #Description
Connector: CN8
RJ-45 Ethernet Port
14-20 mA input +
2Return - (Common).
Connector: CN9
Terminal #Description
Connector: CN15
Factory Cable to MACF (CN1)
Note: Electronically connected to common

Table of Contents