EasyManua.ls Logo

Technische Alternative ESR 31 - User Manual

Technische Alternative ESR 31
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ESR 31
Version 1.8-4
Simple solar control unit
Régulateur solaire simple
Regolatore semplice a energia solare
Regulación solar sencilla

Table of Contents

Questions and Answers

  • K
    Kristen DunlapAug 3, 2025
    What to do if my Technische Alternative ESR 31 Control Unit displays incorrect temperatures?
    • T
      Theresa StevensAug 4, 2025
      If your Technische Alternative Control Unit displays incorrect temperatures, values such as -999 or 999 do not necessarily indicate a material or terminal error; this can happen if a sensor short-circuits or if there is an interruption. Ensure that the correct sensor types (KTY or PT1000) are selected in the menu under SENSOR. You can also check the sensor by replacing the suspected defective sensor with a working one on the strip terminal and observing the display.
  • G
    Gregory SmithAug 14, 2025
    How to troubleshoot malfunction with realistic temperature values on my Technische Alternative ESR 31?
    • B
      Billy SmithAug 14, 2025
      If your Technische Alternative Control Unit malfunctions but shows realistic temperature values, check the program number, switch-on and switch-off thresholds, and the set differential temperatures. Verify if the settings in the submenus have been changed. See if the output can be switched on and off in manual mode. Ensure all sensors are connected to the correct terminals. You can also heat up the sensor using a cigarette lighter and observe the display.
  • N
    Natasha GayAug 25, 2025
    Why is my Technische Alternative Control Unit not in operation despite having supply voltage?
    • J
      James LoweryAug 25, 2025
      If your Technische Alternative Control Unit isn't working even with supply voltage connected, the 3.15A quick-blowing fuse that protects the control system and the output should be checked and replaced if necessary.

Summary

Safety and Maintenance

Safety Requirements

Installation and wiring safety must be performed by competent personnel in a zero-voltage state.

General Operational Rules

System Use Rules

Applicable rules for correct use, manufacturer liability, and system protection.

Hydraulic Diagrams and Programs

Program 0: Factory Settings

Factory default settings for solar thermal systems, pump control, and excess temperature shut-down.

Parameter Menu (PAR)

Menu MEN Functions

Status Display and Error Codes

Installation Procedures

Sensor Installation

Instructions for correctly installing various types of sensors for optimal performance.

Electrical Connections

Troubleshooting Guide

Technische Alternative ESR 31 Specifications

General IconGeneral
PWM outputs2
EnclosurePlastic
DisplayLCD with backlight
CommunicationCAN bus
Power Supply24 V AC/DC
Operating Temperature-10°C to +50°C

Related product manuals