TECNA WELD TESTER TE1700
Current date and time.
For setting the mains frequency on the site where the instrument is
taking measurements. Choose between 50 Hz and 60 Hz. The value of
this parameter affects the measurements made on AC current
generators.
Allows you to select which statistical data the instrument must store
for each acquired spot. If NORMAL mode was selected, only spots
numeric data will be saved but if you selected ADVANCED mode, then
the numeric data and the waveforms associated with each spot will be
saved. When switching between the two modes, the instrument's
memory must be cleared.
WARNING: If using the ADVANCED mode, the acquisition rate
decreases to minimum, due to the greater amount of data to be
processed.
PAGE 44