S.p.A. ITEM TE550 Instruction manual
2.11 - CHECK INPUT
-TE550 VER. 3.31--
FEATURES MENU
PROGRAM COPY
>CHECK INPUT
This menu displays the input status on the welding control unit. It is uses for check both the
efficiency and the proper working of the external devices connected to the control unit and
necessary for using the welder.
CHECK INPUT
>START OFF
AUX OFF
AUX 3 OFF
The following inputs are mentioned in the list which may be scrolled by means of the
and
keys.
PARAMETER PARAMETER DESCRIPTION VALUE
START It indicates the status of the cycle start signal ON – OFF
AUX It indicates the status of the auxiliary signal ON – OFF
AUX 3 It indicates the status of the auxiliary 3 signal ON – OFF
DOUBLE STROKE It indicates the status of the double stroke ON – OFF
START2 It indicates the status of the cycle 2 start signal ON – OFF
TERM/FLUX It indicates the status of the thermostat signal ON – OFF
PRG RECALL 1 It indicates the status of the recall 1 signal ON – OFF
PRG RECALL 2 It indicates the status of the recall 2 signal ON – OFF
PRG RECALL 3 It indicates the status of the recall 3 signal ON – OFF
PRG RECALL 4
It indicates the status of the recall 4 signal
ON – OFF
PRG RECALL 5
It indicates the status of the recall 4 signal
ON – OFF
SAFETY START 1 It indicates the status of the two-hand control push-button 1 signal ON – OFF
SAFETY START 2 It indicates the status of the two-hand control push-button 2 signal ON – OFF
(When the option item 50200 is present)
RESET DRESSING It indicates the status of the accomplished electrodes dressing signal ON – OFF
WELD / NO WELD It indicates the status of the external weld / no weld signal ON – OFF
RESET ERROR It indicates the status of the errors clear signal ON – OFF
RESET ELECTRODE It indicates the status of the accomplished electrodes change signal ON – OFF
The input status is represented as enabled (closed input with COM1) by means of the wording
ON, while it is represented as disabled by means of the wording OFF.