Group 06: Automatic Program Operation
Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
06-29
Operation
Time Setting
of Speed-
Stage 13
0.0~6000.0 0.0 *1
06-30
Operation
Time Setting
of Speed-
Stage 14
0.0~6000.0 0.0 *1
06-31
Operation
Time Setting
of Speed-
Stage 15
0.0~6000.0 0.0 *1
06-32
Operation
Direction
Selection of
Speed-Stage 0
0: Stop
1: Forward
2: Reverse
0
06-33
Operation
Direction
Selection of
Speed-Stage 1
0: Stop
1: Forward
2: Reverse
0
06-34
Operation
Direction
Selection of
Speed-Stage 2
0: Stop
1: Forward
2: Reverse
0
06-35
Operation
Direction
Selection of
Speed-Stage 3
0: Stop
1: Forward
2: Reverse
0
06-36
Operation
Direction
Selection of
Speed-Stage 4
0: Stop
1: Forward
2: Reverse
0
06-37
Operation
Direction
Selection of
Speed-Stage 5
0: Stop
1: Forward
2: Reverse
0
06-38
Operation
Direction
Selection of
Speed-Stage 6
0: Stop
1: Forward
2: Reverse
0
06-39
Operation
Direction
Selection of
Speed-Stage 7
0: Stop
1: Forward
2: Reverse
0
06-40
Operation
Direction
Selection of
Speed-Stage 8
0: Stop
1: Forward
2: Reverse
0
06-41
Operation
Direction
Selection of
Speed-Stage 9
0: Stop
1: Forward
2: Reverse
0
06-42
Operation
Direction
Selection of
Speed-Stage
10
0: Stop
1: Forward
2: Reverse
0
06-43
Operation
Direction
Selection of
Speed-Stage
11
0: Stop
1: Forward
2: Reverse
0
06-44
Operation
0: Stop 0
Group 06: Automatic Program Operation
Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
Direction
Selection of
Speed-Stage
12
1: Forward
2: Reverse
06-45
Operation
Direction
Selection of
Speed-Stage
13
0: Stop
1: Forward
2: Reverse
0
06-46
Operation
Direction
Selection of
Speed-Stage
14
0: Stop
1: Forward
2: Reverse
0
06-47
Operation
Direction
Selection of
Speed-Stage
15
0: Stop
1: Forward
2: Reverse
0
* If the maximum output frequency of motor is over
300HZ, the frequency resolution is changed to 0.1Hz
Group 07: Start /Stop Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
07-00
Momentary
Power
Loss/Fault
Restart
S
election
0: Disable
0
1: Enable
07-01
Fault Auto-
Restart Time
0~7200 0
07-02
Number of
Fault Auto-
Restart
Attempts
0~10 0
07-03 Reserved
07-04
Direct Start at
Power on
0: When the
external run
command is
enabled, direct
start at power up
1
1: When the
external run
command is
enabled, unable
to direct start at
power-up.
07-05
Delay of
Direct Start at
Power on
1.0~300.0 3.5
07-06
DC Injection
Braking
Starting
Frequency
0.0~10.0 0.5

Other manuals for TECO A510s Series