30
Group 11: Auxiliary Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
575V: 540~570 555
690V: 540~684 555
11-49
Zero-servo
Gain
0.01~5.00 1.00
11-50
Zero-servo
Count
0~4096 12
11-51
Braking
Selection of
Zero Speed
0: Disable
0
1: Enable
11-52
Droop Control
Level
0.0~100.0% 0.0 *1
11-53
Droop Control
Delay
0.01~2.00 0.2 *1
11-54
Initialization of
Cumulative
Energy
0: Do not Clear
Cumulative
Energy
0
*1
1: Clear
Cumulative
Energy
11-55
STOP Key
Selection
0: Stop Key is
Disabled when
the Operation
Command is
not Provided
by Operator.
1
1: Stop Key is
Enabled when
the Operation
Command is
not Provided
by Operator.
11-56
UP/DOWN
Selection
0: When
UP/DOWN in
Keypad is
Disabled, it will
be Enabled if
Pressing
ENTER after
Frequency
Modification.
0
1: When
UP/DOWN in
Keypad is
Enabled, it will
be Enabled
upon
Frequency
Modification.
11-57 Reserved
11-58
Record
Reference
Frequency
0: Disable
0
*1
1: Enable
11-59
Gain of
Preventing
Oscillation
0.00~2.50 *
11-60
Upper Limit of
Preventing
Oscillation
0~100 *
11-61 Time 0~100 0
Group 11: Auxiliary Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
Parameter of
Preventing
Oscillation
11-62
Selection of
Preventing
Oscillation
0: Mode1
1
1: Mode2
2: Mode3
11-63
Strong
Magnetic
Selection
0: Disable
1
1: Enable
11-64
Acceleration
Speed Gain
Adjustment
0.1~10.0 1.0
11-65
Target Main
Circuit Voltage
200V: 200V~400V
370
400V: 400V~800V
740
575V: 520V~1040V
962
690V: 624V~1248V
1154
11-66
2 Phase/ 3
Phase PWM
Switch
Frequency
6.00~60.00 20 Note2
11-67
Soft PWM 2
Frequency
Range
0~12000 0 Note2
11-68
Soft PWM 2
Switch
Frequency
6.00~60.00 20 Note2
11-69
Gain of
Preventing
Oscillation 3
0.00~200.00 5.00 Note1
11-70
Upper Limit of
Preventing
Oscillation 3
0.01~100.00 5.00 Note1
11-71
Time
Parameter of
Preventing
Oscillation 3
0~30000 100 Note1
11-72
Gain of
Preventing
Oscillation for
switch
frequency 1
0.01~300.00 30.00 Note1
11-73
Gain of
Preventing
Oscillation for
switch
frequency 2
0.01~300.00 50.00 Note1
11-76
Droop
Frequency
Level 1
0.00~599.00 0.00 Note4
11-77
Droop
Frequency
Level 2
0.00~599.00 0.00 Note4
11-78
Droop Torque
Offset Value
0.00~100.00 0.00 Note4
*: Refer to the attachment 1 in our instruction manual..
** If the maximum output frequency of motor is over
300HZ, the frequency resolution is changed to 0.1Hz