47
LED display Corrective action
OH2
(flash)
Inverter over
heating
warning
ï‚· Multi-function input
function set incorrectly.
ï‚· Check wiring
OT
(flash)
over torque
detection
ï‚· Check over torque
detection parameters
(08-15 / 08-16).
ï‚· Check and reduce
motor load, check and
operation duty cycle.
UT
(flash)
under torque
detection
ï‚· Check under torque
detection parameters
(08-19 / 08-20).
ï‚· Check load /
application.
bb1
(flash)
External
baseblock
ï‚· Multi-function input
function set incorrectly.
ï‚· Check wiring
bb2
(flash)
External
baseblock
bb3
(flash)
External
baseblock
bb4
(flash)
External
baseblock
bb5
(flash)
External
ï‚· Multi-function input
function set incorrectly.
LED display Corrective action
baseblock
ï‚·
Check wiring
bb6
(flash)
External
baseblock
bb7
(flash)
External
baseblock
bb8
(flash)
External
baseblock
OS
(flash)
Motor over
speed
ï‚· Check ASR parameters
group 21.
ï‚· Check PG parameters
ï‚· Check overspeed
parameters 20-20/20-
12.
PGO
(flash)
PG open
circuit
ï‚· Check PG wiring.
ï‚· Check PG power-
supply.
ï‚· Make sure brake is
released.
DEV
(flash)
Speed
deviation
ï‚· Check load
ï‚· Make sure brake is
released.
ï‚· Check PG wiring.
ï‚· Check PG parameters
20-23/20-24.
ï‚· Increase Acceleration /
deceleration time.
OL1
Motor overload
ï‚·
Check V/f curve.
ï‚· Check motor rated
current
ï‚· Check and reduce
motor load, check and
operation duty cycle.
OL2
Inverter
ï‚· Check V/f curve.