48
LED display Corrective action
overload
ï‚· Replace inverter with
larger rating.
ï‚· Check and reduce
motor load, check and
operation duty cycle.
CE
(flash)
communication
error
ï‚· Check connection
ï‚· Check host computer /
software.
CLA
over current
protection level
A
ï‚· Check load and duty
cycle operation.
CLB
over current
protection level
B
ï‚· Check load and duty
cycle operation.
Retry
(flash)
retry
ï‚· Warning disappears
after automatic reset.
ES
(flash)
External
emergency
stop
ï‚· Turn off run command,
and remove external
emergency stop
command.
EF1 ( flash )
External fault
(S1)
ï‚· Multi-function input
function set incorrectly.
ï‚· Check wiring
ï‚· Multi-function input
function set incorrectly.
ï‚· Check wiring
EF2 ( flash )
External fault
(S2)
EF3 ( flash )
External fault
(S3)
LED display Corrective action
EF4 ( flash )
External fault
(S4)
EF5 ( flash )
External fault
(S5)
EF6 ( flash )
External fault
(S6)
EF7 ( flash )
External fault
(S7)
EF8 ( flash )
External fault
(S8)
EF9 ( flash )
error of
forward/revers
al rotation
ï‚· Check run command
wiring
SE01
Rang setting
error
ï‚· Check parameter
setting.
SE02
Digital input
terminal error
ï‚· Check multi-function
input setting.
SE03
V/f curve error
ï‚· Check V/F parameters
SE05
PID selection
error
ï‚· Check10-00 and 10-01
ï‚· Check 10-29 and 10-25