LED display Corrective action
ï‚· Check 10-29 and 10-03
HPErr
Model
selection error
ï‚· Check inverter capacity
setting 13-00.
SE07
PG card error
ï‚· Install PG feedback
card.
ï‚· Check control mode.
ï‚· Set right type for PM
Encoder Type (22-08)
and power on again.
SE08
PM Motor
mode error
ï‚· Check control mode.
SE09
PI setting error
ï‚· Check pulse input
selection (03-30) and
PID source (10-00 and
10-01).
FB
(flash)
PID feedback
breaking
ï‚· Check feedback wiring
ï‚· Replace feedback
sensor.
USP
(flash)
Unattended
Start
Protection
ï‚· Remove run command
or reset inverter via
multi-function digital
input (03-00 to 03-07 =
17) or use the RESET
key on the keypad to
reset inverter.
ï‚· Activate USP input and
re-apply the power.
STP0
Zero Speed
Stop Error
ï‚· Adjust frequency
command
STP2
External
Terminal Stop
Error
ï‚· Remove the run
command from external
terminal
EnC
Encoder Error
ï‚· Check encoder wiring
ï‚· 17-07 PG pulse number
setting is not
corresponding to the
encoder.
ï‚· Replace the encoder.
LED display Corrective action
RunEr
Wrong running
direction Error
ï‚· Revise the command
among 11-00, jog and
DI control to see if any
difference
PArEr
Parameter
setting error
ï‚· Please refer to our
instruction manual for
correct setting
STP1
Direct start
warning
ï‚· Remove the run
command from the
terminal first, and
enabled later.
FirE
Fire mode
enabled
ï‚· Check the environment
and confirm the fire
status. If no fire, turn off
the power and power on
again.
AdCEr
Voltage on C/B
error
ï‚· Check the voltage on
the control board.
EPErr
EEPROM Save
error
ï‚· Restore factory setting,
then cut off the power
and power on again.
ï‚· If warning again,
replace control board.
bdErr
Control board
error
ï‚· Replace the control
board.
Parameter
Lock
ï‚· Lifting the parameter
lock key code, to enter
the correct parameter
for 13-07
Set password
failed
ï‚· Enter the correct
parameter for 13-07 to
enable the parameter
lock key