7-12
08H : Diagnostic function
The sub-function code 0000H is able to check communication signal between Master and Slaver. Data
content is random value.
Ex: Use the diagnostic function for ID=01H
ASCII Mode
Query PC Servo
Response Servo PC (OK)
Servo PC (ERROR)
STX ‘ : ’ STX ‘ : ’ STX ‘ : ’
‘ 0 ’ ‘ 0 ’ ‘ 0 ’
ADR
‘ 1 ’
ADR
‘ 1 ’
ADR
‘ 1 ’
‘ 0 ’ ‘ 0 ’ ‘ 8 ’
Function Code
‘ 8 ’
Function Code
‘ 8 ’
Function
Code
‘ 8 ’
‘ 0 ’ ‘ 0 ’ ‘ 0 ’
(HI)
‘ 0 ’
(HI)
‘ 0 ’
Exception
code
‘ 3 ’
‘ 0 ’ ‘ 0 ’ ‘ 7 ’
Sub-
Function
(Lo)
‘ 0 ’
Sub-
Function
(Lo)
‘ 0 ’
LRC
‘ 4 ’
‘ A ‘ A END1 (CR) (0DH)
‘ 5 ’ ‘ 5 ’ END0 (LF) (0AH)
‘ 3 ’ ‘ 3 ’
Data
(word)
‘ 7 ’
Data
(word)
‘ 7 ’
‘ 1 ’ ‘ 1 ’
LRC
‘ B ’
LRC
‘ B ’
END1 (CR) (0DH) END1 (CR) (0DH)
END0 (LF) (0AH) END0 (LF) (0AH)
RTU Mode
Query PC Servo
Response Servo PC (OK)
Servo PC (ERROR)
ADR 01H
ADR 01H
ADR 01H
Function Code
08H
Function Code
08H
Function Code
88H
(HI) 00H
(HI) 00H
Exception
code
03H
Sub-
Function
(Lo) 00H
Sub-
Function
(Lo) 00H
CRC(Lo) 06H
A5H
A5H
CRC(Hi) 01H Data
(word)
37H
Data
(word)
37H
CRC(Lo) DAH
CRC(Lo) DAH
CRC(Hi) 8DH
CRC(Hi) 8DH