Chapter 3 Program Tools 54
(4) SET (system setting)
content default
ID SET 01
Æ
ID setting (00~99)
REMOTE I/O
N
Æ
Remote I/O Mode
(N: none M: Master S: Slave)
BACK LIGHT
×
Æ
Back light mode
(: always light ×: light for 10s after pressed.)
M KEEP
Æ
M: non-Volatile (:Volatile ×: Non- Volatile)
I/O NUMBER 0
Æ
Setting expansion I/O module number (0~3)
I/O ALARM
Æ
Siren setting when is not available to Expansion
I/O Points (:Yes ×:No)
C KEEP
×
Æ
in stop/run switching, Counter Present Value
Keeping (:Yes ×:No)
Z SET
×
Æ
Enable or disable keypad input Z01-Z04
(:enable ×:disable)
RS485 SET 03
Æ
Setting the form and baud rate of RS-485
DATA REG.
U
Æ
Setting the Data Register type
(U: 16bit-unsiged S: 16bit-sign)
M KEEP function is available for keeping M status and current value of T0E/T0F when power is re-supplied
after loss.
Now Press:
Move the cursor
SEL Begin to edit.
‘SEL then ‘/
Move the cursor for ‘ID SET’ item and ‘RS485 SET’ item
‘SEL then ‘ /
1. ID SET = 00~99 ; I/O NUMBER = 0~3
2. REMOTE I/O = NMSN
3. BACK LIGHT ; C KEEP ; Z SET = ×
4. M KEEP; I/O ALARM = ×
5. RS485 SET = (0~3)(0~5)
6. DATA REG. = US
OK Confirm the Edition Data
ESC 1. Cancel the setting when pressed ‘SEL
2. Back to Main Menu(save edit data)
When IO LINK is selected, ID setting range is 0~7, which should be continuous.
ID=0 default as Master, ID=1~7 default as Slave.
When REMOTE I/O is selected, the distribution of the remote I/O is as follows:
Master Slave
Remote Input X01~X0C
I01~I0C
Remote Output Y01~Y08
Q01~Q08
The high bit of RS485 SET detects the form of RS-485, and the low bit detects the baud rate of RS-485.
More detailed to see chapter 7: 20 Points RS485 type Models Instruction.