32 
 
 
 
 
 
 
 
Function  F_ 
Function Description 
Unit Range 
Factory 
setting 
Page Note
Reverse Lock-Out  22 
0: REV run   
1: REV run Lock-Out 
1 0 ~ 1 0 40 
 
Momentary power 
loss 
23 
0: enabled 
1: disabled 
1 0 ~ 1 0 41 
 
Auto restart  24  Number of Auto-restart times  1  0 ~ 5  0  41   
Factory setting  25 
 010: Constants initialization to 50Hz system 
 020: Constants initialization to 60Hz system 
42 *2
SP2 frequency  26  SP2 frequency  0.1Hz 1.0~200Hz  20  42  *4
SP3 frequency  27  SP3 frequency  0.1Hz 1.0~200Hz  30  42  *4
Direct start  28 
 0:enable 
1:disable 
1 0 ~ 1 1 42 *5
Software version  29   CPU program version    43   
Fault Log  30   Fault log for three faults.    43   
NOTE: 
*1: Indicate this parameter can be adjusted during running mode. 
*2: Please refer to F_25. 
*3: If the setting range is above 100, the setting unit becomes 1. 
*4: New function for CPU version V1.9 and above. 
*5: New function for CPU version V2.1 and above 
Parameter function description 
F_00 Factory adjustment parameter. Do not change. 
 
F_01 : Acceleration time = 0.1 ~ 999 sec 
F_02 : Deceleration time = 0.1 ~ 999 sec 
 
1.  Acceleration / Deceleration time calculation formula: 
 
Setting Frequency Accelerate time = F_01 x 
60 Hz 
 
Setting Frequency Decelerate time = F_02 x 
60Hz 
 
 
 
 
 
 
 
 
 
 
F_01 F_02 
Hz 
Time