40 
 
 
 
 
             Hz 
 
             Time 
 
  
        Run/Stop               on                 off         on 
 
  
  F_20=4                          off       on     
  
5.  F_19, F_20 = 5: Auto Reset when inverter faults. 
 
F_21: Multi-function output terminal control = 1 ~ 3 
 
1.  F_21 = 1: Run mode signal 
2.  F_22 = 2: At Frequency Speed Signal 
3.  F_21 = 3: Fault signal 
 Terminal1 and2 of TM2 are activated at CPF, OL1, OL2, OCS, OCA, OCC, Ocd , Ocb , OVC , 
LVC , OHC. 
 
      Hz 
 
             Time 
 
 
 F_21=1 
      Terminal 1 & 2          on 
 
 
 
        F_21=2 
     Terminal 1 & 2                   on 
 
 
 
F_22: Reverse Lock-Out     = 0: REV command  
  = 1: REV command Lock-out 
 
NOTE:  
When F_04 is set to 1 (reverse), F_22 cannot be set to 1, in order to properly lockout 
a motors direction, F_04 must be set at 0 before setting F_22 to 1.