The following figure shows the DGP alarm control level dialog:
Alarm control level no
Each door can have up to six alarm control levels. Alarm control levels can be
assigned to the door’s IN and OUT readers separately.
Enter a number for the alarm control level, and, optionally, a name to identify the
alarm control level.
Time zone
Specify a time zone to apply to this alarm control level. The alarm control level is
only available if the time zone is valid.
Reset system alarms
A user with the appropriate alarm group can reset latching system alarms at the
door. The user’s alarm group and the door’s alarm control level must allow
arming, disarming, and resetting. The “Latching system alarms” system option
must also be enabled on the ChallengerPlus panel. Refer to the ChallengerPlus
Programming Manual for details of latching system alarms.
Auto isolate
When a user with the appropriate alarm group arms an area, all unsealed inputs
will be automatically isolated. The system is armed without causing an alarm.