Lock relay 1
Specify the relay to be activated to unlock the door.
Program the relay using the scheme described in the Flexible device locations
section on page 18.
Lock relay 2
This relay is reserved for future use.
Door input 1
Specify the input used to indicate if the door is open or closed. This is usually the
reed switch.
Program the input using the scheme described in the Flexible device locations
section on page 18.
Door input 2
Specify the input connected to the lock monitor on Strike, Maglock, and Drop bolt
lock types.
Program the input using the scheme described in the Flexible device locations
section on page 18.
Forced relay
Specify the relay to be activated when an input is in a “Forced Door” condition,
e.g. the door has been opened without a valid command.
Program the relay using the scheme described in the Flexible device locations
section on page 18.
Warning relay
Specify the relay to be activated during the “Warning time” when the shunt timer
is about to expire, e.g. may be used to activate a buzzer above a door to indicate
the door needs to be closed.
Program the relay using the scheme described in the Flexible device locations
section on page 18.
DOTL relay
Specify the relay to be activated when an input is in a DOTL condition, e.g. the
door left open after the shunt timer has expired.
Program the relay using the scheme described in the Flexible device locations
section on page 18.
Egress input
Specify the input that activates the egress function for the door being
programmed.
Program the input using the scheme described in the Flexible device locations
section on page 18.