EasyManuals Logo

Tecsis F7301 User Manual

Tecsis F7301
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
Betriebsanleitung/Operating manual
F7301/F73C1/F73S1
www.tecsis.de BD_BE 990 c 33
Connection assignment version ATEX/IECEx 7.2
ATEX Ex ib,
4…20 mA,
2-wire
Power supply
UB+
1
Power supply
0V/UB-
3
Signal
S+
1
Signal
S-
3
Shield
Housing
Cable assignment
cable colour
2-wire
BN
UB+/S+
WH
---
BU
0V/S-
BK
---
Only when using the tecsis standard cable, for example. EZE53X011016
Connection assignment version SIL-3 acc. EN 62061:2005 7.3
4…20 mA,
2-wire
4…20 mA,
3-wire
0…10 V,
3-wire
Power supply
UB+
1 1 1
Power supply
0V/UB-
3 3 3
Relay
UR+
2 2 2
Relay
UR-
4 3 3
Signal
S+
1 4 4
Signal
S-
3 3 3
Shield
Housing Housing Housing
Cable assignment
cable colour
2-wire
3-wire
BN
UB+/S+
UB+
WH
UR+
UR+
BU
0V/S-
0V/S-/UR-
BK
UR-
S+
Only when using the tecsis standard cable, for example. EZE53X011016