EasyManua.ls Logo

Tefcold SFI Series - Page 14

Tefcold SFI Series
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
EN
Reduced SET / Economy LED
Permanently on: Energy
Savng actve
Flashng: Reduced set actve
Quck ashng: Access to
level2 parameters
O: Otherwse
Fans LED
Permanently on: Fans actve
O: Otherwse
Compressor LED
Permanently on: Compressor
actve
Flashng: Delay, protecton or
actvaton blocked
O: Otherwse
Defrost LED
Permanently on: Defrost
actve
Flashng: Actvated manually
or from DI
O: Otherwse
Aux LED
Permanently on: Aux output
actve
Flashng: Deep coolng Cycle
actve
O: Aux output not actve
Alarms LED
Permanently on: alarm actve
Flashng: alarm acknowledged
O: otherwse
°C LED
Permanently on: °C settng
(dro = 0)
O: otherwse
°F LED
Permanently on: °F settng
(dro = 1)
O: otherwse
Digital thermostats contain many parameters within themselves. Your
t
hermostat has factory settings by default and does not require any adjust-
ment, however, the user has the option to change the mode on EWPlus 978
thermostat. EWPlus 978 thermostat may operate in three different modes.
1. Freezer
2. Meat Mode
3. Cooler