EasyManua.ls Logo

Tekmar 562 - Application 562-2

Tekmar 562
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2017 tekmar 562
_
D - 08/17
7 of 24
Application 562-2
Mechanical
----------------------------------------------------------
Electrical
-----------------------------------------------------------
C
R
AWAY
W
Rh1
W1
Rh2
W2
Rc
Y1
G
C
R
AWAY
S1
S2
SEN
COM
C
R
W
G
Y
Legend
B1 = Boiler
BP = Boiler Pump
C1 = Air Conditioner
The WiFi Thermostat 562 operates a first stage radiant floor and a second stage furnace
for heating, and an air conditioner for cooling.
C1
WiFi Thermostat 562
F1
B1
T1
S1
S1
S2
S2
V1
ZVC1
ZVC1
BP
PS
F1 = Furnace
PS = System Pump
T1 = WiFi Thermostat 562
V1 = Zone Valve
S1 = Optional Floor Sensor 079
S2 = Optional Indoor Sensor 084
ZVC1 = Zone Valve Control 304V, 306V
Furnace
Terminals
J1 J2 J3
RELAY
POWER
JUMPER
ON
OFF
Thermostat
jumpers:
J1 = On
J2 = Off
J3 = Off
and install field jumper
wire from Rh2 to Rc