4.2.6 Capacitance
Range
Resolution
Accuracy
6nF
1pF
±( 5.0% of rdg +20 digits)
60nF
10pF
±(3.0% of rdg +20 digits)
600nF
100pF
± (5.0% of rdg+10 digits)
6F
1nF
60F
10nF
600F
100nF
6mF
1F
±( 5.0% of rdg +20 digits)
4.2.7 Temperature
Range
Resolution
Accuracy
-200~0
1
±(5.0% of rdg + 4)
0~400
±(2.0% of rdg+ 3)
400~1200
±(2.0% of rdg+ 2)
Note: The specifications of temperature don’t include
thermocouple errors.
4.2.8 Current
DCA:
Range
Resolution
Accuracy
600A
0.1A
±(1.5% of rdg+3 digits)
6000A
1A
60mA
0.01mA
±(1.5% of rdg+3 digits)
600mA
0.1mA
6A
1mA
±(1.5% of rdg+5 digits)
10A
10mA