2.3.5 Hz %
At V~, A, mA and A.
1. Press it to start the frequency counter.
2. Press it again to enter duty (load factor) mode.
3. Press it again to exit the frequency counter mode.
2.3.6 MAX/MIN
This key is for measuring maximum value and minimum
value.
1. Press it to enter Max/Min mode.
2. Press it again; the LCD will display the Maximum
Value.
3. Press it again; the LCD will display the Minimum
Value.
4. Press and hold it for two seconds, the meter will
return to normal measurement state.
(Except Hz/Duty and Capacitance)
3. FUNCTION DESCRIPTION
3.1 General Functions
3.1.1 DATA HOLD mode
Data Hold mode makes the meter stop updating the display.
Enabling Data Hold function in autorange mode makes the
meter switch to Manual ranging mode, but the full-scale
range remains the same. Data Hold function can be
cancelled by changing the measurement mode, pressing
RANGE key, or push key again.