BĆ4
Jitter 1.1 ps RMS + 4 ppm of position (typical)
2.0 ps RMS + 5 ppm of position max
Freq = 2.5 GHz, DC/1,
V
in
= 200 mV
pĆp
,HF=Off,
Enhanced = On
May require trigger level adjustment to avoid
250 ps pulse width when triggering on trailing
edge
Trigger source External Direct, Internal Clock, or
External Prescaler
Trigger mode
Auto Free runs after 20 ms timeout
Normal Acquisition only after trigger event
Maximum pĆp trigger input
Direct 1 V
pĆp
(1)
10 V
pĆp
(10)
Prescaler 2.5 V
pĆp
Maximum safe trigger input voltage
Direct "1.5V(1)
"15 V, ≤5V
RMS
(10)
Prescaler "2.5 V
External trigger attenuation 1 and 10
Trigger level -1Vto+1V,1 attenuation,
-10Vto+10V,10 attenuation
Trigger level resolution 1mV,1 attenuation
10 mV, 10 attenuation
Trigger accuracy 10% of full scale
Trigger sensitivity
Direct - DC coupled 1: 100 mV, DC to 3 GHz
50 mV, DC to 4 GHZ (typical)
10: 1 V, DC to 3 GHz
(Auto, Enhanced Off, Auto holdoff, HF Off)
May require trigger level adjustment to avoid
250 ps pulse width when triggering on trailing
edge for stable triggering