O
perating
Instructions-2235
Service
5
.
Adjust
the
Β
D
ELAY
TIME
P
OSITION
control
to
move
2
.
U
se
equal-length coaxial cables,
or
the
two
10
Χ
t
he
intensified
zone
to
the
leading
edge
of
the
first
pulse
of
p
robes
supplied
with
t
he
instrument,
to
apply
the
h
orizontal
interest
;
then
fine
adjust
u
ntil
the
rising
p
ortion
is
centered
signal
(X-axis)
to
the
CH
1
OR
Χ
i
nput connector
and
to
at
any
convenient
vertical
graticule
line
.
apply
the
vertical
signal
(Y-axis)
to
the
CH
2
OR
Υ
input
connector
.
6
.
R
ecord
t
he
Β D
ELAY
TIME
P
OSITION
control
d
ial
setting
.
3
.
Select
Χ
-
Υ
mode
b
y
rotating
the
Α
S
EC/DIV
switch
to
its
fully
counterclockwise
p
osition
.
7
.
Adjust
the
Β D
ELAY
TIME
P
OSITION
control
clockwise
u
ntil
the
rising
p
ortion
of
the
second
pulse
of
4
.
R
otate
the
Α
I
NTENSITY
control
clockwise
until
two
interest
is
p
ositioned
to
the
same
vertical
reference
line
dots
are displayed
.
The
display
can
be p
ositioned
selected
in
step
5
.
h
orizontally
with
t
he H
orizontal
P
OSITION
control
and
vertically
with
t
he
Channel
2
P
OSITION
control
.
8
.
R
ecord
the
Β D
ELAY
TIME
P
OSITION
control
dial
setting
.
NOTE
T
h
e
dis
p
lay
ob
tained
w
h
e
n
sinusoidal
signals
are
9
.
U
se
the
following
formula
to
calculate
the
time
ap
plied
to
t
he
Χ
-
and
Υ
-
αχί
s
Is
called
α
L
issa
j
o
u
s
difference
:
figu
r
e
.
T
h
is
display
Is
commonly
use
d
to
com
pa
re
t
he
f
r
equen
cy
an
d
ph
ase
relationships
of
two
in
pu
t
sig
n
als
.
T
h
e
frequency
relations
h
ip
of
t
h
e
two
inp
u
t
Time
second
first
Α
S
EC/DIV
signals
dete
r
mines
t
h
e
pattern
seen
.
The
p
atter
n
will
Difference
=
dial
-
d
ial
switch
setting
be
sta
b
le
only
if
α
commo
n
divisor
exists
between
t
he
(delayed
swee
p
)
setting
setting
(delay
time)
two
f
re
qu
e
n
cies
.
)
SI
N
G
LE
-S
WEEP
DIS
PL
AY
1
.
Obtain
α
Signal
Display
.
2
.
F
or
random
signals,
set
the
Α
T
RIGGER
LEVEL
control
to
trigger
the
sweep
on
α
signal
that
is
approximately
the
same
amplitude
as
the
random
signal
.
3
.
M
omentarily
press
in
the
Α TRIGGER
SGL
S
WP
RESET
push
button
.
If
no
trigger
signal
is
present,
the
TRIG'D-READY
light
should
illuminate
to
indicate that
the
Α
Sweep
Generator
circuit
is
set
to
initiate
α
sweep
w
hen
α
trigger
signal
is
r
eceived
.
The
n
ext
trigger
pulse
will
initiate
the
sweep,
and
α
single
trace
will
b
e d
isplayed
.
4
.
When
t
he
single
sweep
is
triggered
and
t
he
sweep
com
p
leted,
the
Sweep-Logic
circuitry
is
then
locked
out
.
Another
sweep
cannot
b
e
generated
until
the
SGL
S
WP
RESET
p
ush
button
is
again
pressed
i
n
to
set the
Α
Swee
p
Generator
to
the
READY
condition
.
T
V
SIG
N
A
L
DIS
PL
AYS
Displaying
α
T
V
Line-rate
Signal
1
.
Display
of
the d
esired
T
V
signal
(see
"Signal
Display"
procedure)
.
2
.
Set
the
ΑS
EC/DIV
control
to
10 μ
s,
and
the
Α
&
Β
ΙΝΤ
switch
either
to
CH
1
or
to
CH
2,
as
appropriate
for
t
he
applied
signal
.
3
.
Set
the
Α
T
RIGGERS
LOPE
switch
either
for
α
posi-
tive-going
signal
(lever
up,
if
the
applied
TV
signal
sync
pulses
are
positive-going)
or
for
α
n
egative-going
signal
(le-
ver
down,
if
the
TV
sync
pulses
are
n
egative-going)
.
4
.
Adjust
the
Α
T
RIGGER
LEVEL
control
for
α
stable
display,
and
the
Α
I
NTENSITY
control
for
d
esired
display
brightness
.
If
necessary,
adjust
the
VERTICAL
VOLTS/DIV
control
to obtain
α
trace
h
aving
5 d
ivisions
or
greater
ampli-
tude
with
α
stable
display
.
ΝΟΤΕ
To
examine
α
T
V
L
ine-
r
ate
sig
n
al
i
n
more
d
etail,
eit
h
er
Χ
-
Υ
DIS
PL
AY
th
e
Χ
10
M
ag
n
ifie
r
or
HO
R
IZO
N
TA
L
M
OD
E
functio
n
s
may
be
em
p
loyed
as
pr
evio
u
sly
described
in
t
h
is
1
.
Obtain
α
b
aseline
trace
.
manual
.

Table of Contents

Other manuals for Tektronix 2235

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2235 and is the answer not in the manual?

Tektronix 2235 Specifications

General IconGeneral
BrandTektronix
Model2235
CategoryTest Equipment
LanguageEnglish

Related product manuals