Service
E
qui
p
me
n
t
R
equired
(see
Table
4-1)
:
Calibration
Generator
(Item
1)
50-
Ω
BN
C
Termination
(Item
5)
L
eveled
Si
n
e-
W
ave
Generator
(Item
2)
Test
Oscilloscope
(Item
11)
Time-
M
ar
k Generator
(Item
3)
Screw
d
river
(Item
13)
50-
Ω
Ca
b
le
(Item
4)
L
ow-Capacita
nce Alignment
Tool
(Item
14)
V
ertical
1
.
A
djust H
o
r
izontal
Am
p
lifier
Gai
n
(
R
740
a
n
d
P
OSITIO
N
(
b
ot
h
)
M
i
drange
R
730)
VER
TICA
L
M
OD
E
C
H
1
α
.
Connect
0.1-ms
time
mar
k
ers
f
r
om
t
he time-mark
BW
L
I
M
IT
Off
(
bu
tton out)
generator
via
α 50-
Ω
cab
le
and
α 50-
Ω
te
r
min
atio
n
to
t
he
C
H
C
H
1
V
O
L
TS/DI
V
0
.5
V
1
O
RΧ
input
co
n
necto
r
.
C
H
1
V
O
L
TS/DI
VV
aria
b
le
CA
L
detent
C
h
annel
1
AC-G
N
D-DC
DC
b
.
Align
t
he
first
time
mar
k
er
wit
h
t
h
e
fi
r
st
(extreme
left)
H
o
r
izo
n
tal
vertical
graticule
line
using
t
h
e
H
orizontal
P
OSITIO
N
control
.
P
OSITIO
N
M
idra
nge
HO
R
IZO
N
TA
L
M
OD
E
Α
Α
an
dΒSE
C/DI
V
0
.1
ms
S
E
C/DI
V
V
aria
b
le
CA
L
dete
n
t
Χ
10
M
agnifier
Off (kn
ob
in)
ΒD
EL
AYTIME
P
OSITIO
N
Fu
lly
co
un
tercloc
kwise
Β
T
R
IGG
ER
SL
O
PE
O
UT
LEVEL
F
ully
cloc
k
wise
Α
T
R
IGG
ER
See
AD
JUST
MEN
T
L
OCATIO
N
S
1
a
nd
AD
JUST
MEN
T
L
OCATIO
N
S
3
at
t
h
e b
ac
k
of
t
he
manual
fo
r
test
p
oi
n
ts
and
ad
j
ustme
n
ts
locations
.
I
N
ITIA
L
CO
N
T
R
O
LSE
TTI
N
GS
PR
OC
E
D
URE
ST
EP
S
V
AR
HO
L
DO
FF
N
O
RM
M
ode
Ρ
-
Ρ
A
U
TO
SL
O
PE
O
UT
LEVEL
M
id
r
an
ge
Α
&Β
ΙΝΤ
VER
T
M
OD
E
Α
SOUR
C
E
ΙΝΤ
H
O
R
IZO
N
TA
L
c
.
AD
JU
ST-
Α
Sweep
Gain
(
R
740)
fo
r
1
time
mar
k
e
r
p
er
d
ivision
over
t
he
center
8
divisions
.
ΝΟΤΕ
Wh
en
ma
k
i
n
g
timing
meas
u
reme
n
ts,
use
as
α
refer-
e
n
ce
t
h
e
tips
of
t
h
e
time
mar
k
ers
positioned
at
t
he
ce
n
ter
h
orizontal
graticule
line
.
d
.
Set
t
he
H
O
R
IZO
N
TA
L
M
OD
E
switc
h
to
Β
.
e
.
AD
JU
ST-
Β
Swee
p
Gain
(
R
730)
for
1
time
ma
rk
e
r
per
divisio
n
.

Table of Contents

Other manuals for Tektronix 2235

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2235 and is the answer not in the manual?

Tektronix 2235 Specifications

General IconGeneral
BrandTektronix
Model2235
CategoryTest Equipment
LanguageEnglish

Related product manuals