1 
2 
»■ 
3 
A 
R3401 
R3403 
VR340T 
R3405 
R3407 
R3410 
, B 
R3402 
U3401 
R3404 
C3401 
R3406 
U3402 
R3408 
R3409 
A3411 
? 
J141 • 
6863-27 
c 
® 
Static Sensitive Devices 
See Maintenance Section 
COMPONENT NUMBER EXAMPLE 
Assembly 
Number 
Component Number 
A23 A2R1234 
XT~r 
Subassembiy 
Number
 (if
 used) 
"chemstic 
Circuit 
Number 
Chassis-mounted components have no Assembly Number 
prefix—see end of Replaceable Electrical Parts List 
Figure 10-9. A14—Dynamic Centering board. 
A14—DYNAMIC CENTERING BOARD 
CIRCUIT 
NUMBER 
C3401 
J141 
J141 
R3401 
R3402 
SCHEM 
NUMBER 
6 
6 
6 
6 
6 
CIRCUIT 
NUMBER 
R3403 
R3404 
R3405 
R3406 
R3407 
SCHEM 
NUMBER 
6 
6 
6 
6 
6 
CIRCUIT 
NUMBER 
R3408 
R3409 
R3410 
R3411 
U3401 
SCHEM 
NUMBER 
6 
6 
6 
6 
6 
CIRCUIT 
NUMBER 
U3402 
VR3401 
SCHEM 
NUMBER 
6 
6 
A14—DYNAMIC CENTERING 
2465B/2467B Service 
TEST WAVEFORM SETUP INFORMATION 
The numbered waveforms below were obtained at the test points indicated on the accompanying schematic diagram and 
boarci dolly. The waveforms are representative of signals that may be expected at the associated points when the following 
setup conditions are observed. Any change(s) from the given setup conditions required to produce a given waveform are 
noted with that waveform illustration. Where B Sweep setup conditions are referenced with a waveform, it is assumed that 
the B SEC/DIV knob is set to 100 nsldw unless otherwise noted. 
2465B SETUP 
Connect a 200-mV, 1-kHz squarewave to the CH1 input 
of the oscilloscope using a BNC cable. 
Set: 
VERTICAL MODE 
Input Coupling 
CH1 and CH2 
VOLTS/DIV 
CH1 and CH2 
CH1 and CH2 VAR 
A and B SEC/DIV 
A and B SEC/DIV VAR 
TRIGGER 
MODE 
SOURCE 
COUPLING 
HOLDOFF 
SLOPE 
LEVEL 
CH1 
1 MfiDC 
50 mV 
In detent 
200
 MS
 (knobs locked) 
In detent 
AUTO 
VERT 
NOISE REJ 
In detent 
+ (plus) 
Stably triggered display 
+3V — 
lr^ 
W/READOUT ON, SIGNAL CONSTANTLY CHANGES 
+ 1V-
-1V-
W/READOUT ON, SIGNAL CONSTANTLY CHANGES 
At At readout 
A REF OR DLY POS 1000.0 us readout 
INTENSITY Midrange 
READOUT INTENSITY Minimum (once At 
readout is set) 
All other control settings are irrelevant. 
TEST OSCILLOSCOPE SETUP 
Using a X10 probe with the test oscilloscope, set its 
Trigger Slope, Trigger Level, Volts/Div and Time/Div 
ranges as required to obtain the indicated displays. 
0 
W/READ0UT
 OFF 
-3ms-
+4V
 — 
0 
W/READOUT
 OFF 
-190mV-
0 
(52 MAY LOOK LIKE 53) W/READOUT OFF 
0 
-190MV-
W/READOUT OFF (53 MAY LOOK LIKE 52) 
00mV-
 #///,„
 / , ,„=. « jp
 /tf/
„i«^ 
n 
0 
-150mV-
H 5ms-
mtt- • in
 ill
 mi fi 
VARIES W/READOUT AND VERTICAL POSITION 
H00|»V — 
0 
0V — 
HI Ul It- 1 s 
,\ M 
K 
-5ms 
■*! 
-150mV — »\ 1 " t «V\ " >■'
 :
™ 
VARIES W/READOUT AND VERTICAL POSITION 
+30v- ;,;.-,>» « - ■ , 
+27V — 
ru 
+22V— - - A, y. «- i* >» i: 
VARIES W/READOUT AND VERTICAL POSITION 
TO I
 V 
0 
«/ I.. 
+5V 
VARIES W/READOUT AND VERTICAL POSITION 
] |«-, |«-2.4ms-»j 
100
 M
s B SWEEP SELECTED - W/NO TRIGGER 
0 
0V
 ■ 
^
^»-2
 .
 4ms-*| 
h n n 
HOLDOFF 
A
 AND B
 SEC/DIV KNOBS LOCKED
 1200MS)W/NO
 TRIGGER 
■" 3ms— 
-1.35V 
0 
0 
-3ms-
VARIES W/HORIZONTAL POSITION 
+28V-
-3ms-
VARIES W/HORIZONTAL POSITION 
+
 1
 ,5V — 
0V — 
- 3ms H HOLDOFF
 |
 SWEEP
 | 
B SWEEP 100 nS 
+25V — 
r- -, HOLDOFF 
AMPLITUDE VARIES W/INTENSITY 
A AND B SWEEP 200
 M
S, DLY 0.0 READOUT OFF 
*♦ 
+,2V
T
 r 
+ 10V 1 
IT 
*AMPLITUDE VARIES W/INTENSITY SETTING 
A SWEEP 200
 M
S 
> 
< 
m 
S 
I 
o 
I 
6863-38