00
0000
00
Figure
6-13.
Option 07 DC Inverter circuit board adjustment and test
point locations.
i~
1.3 ms
|
DC LEVEL
Cs
24VDC
O V DC
+0.8 V
SIGNAL &
VOLTAGE CONDITIONS
The
load is an operating oscilloscope.
is the
preferred
test
oscilloscope and
volt-
meter
ground.
The voltmeter
is
a
20.000 Sl/V
multimeter.
Mode switch set to
24 V.
Voltages
and waveform
amplitudes will vary
with
souice voltage.
Q and
P are
identical
to
R and S,
respectively,
during 24 V
operation. During 12
V operation the
amplitude
at Q
and
P is reduced by a
factor of '2.
+0.8 V
0 V DC
-3.0
V
Figure
6-14.
Option 07 DC Inverter
idealized waveforms.
6-30