Commands Listed in Alphabetical Order
Arguments
<NR3> isafloati
ng point number that specifies the threshold, in volts.
ECL specifies a preset ECL high level of -1.3V.
TTL specifies a preset TTL high level of 1.4V.
Examples
BUS:LOWERTHRESHOLD:CH1 TTL sets the CH1 lower threshold to 800mV.
BUS:LOWERTHRESHOLD:CH1? might return :BUS:LOWERTHRESHOLD:CH1
-800.0000E-3
indicatingtheCH1lowerthresholdis-800mV.
BUS:LOWerthreshold{:MATH|:MATH1}
This command specifies the lower threshold for the math waveform. This will
apply to all search and trigger types that use the math waveform.
Group
Bus
Syntax
BUS:LOWerthreshold{:MATH|:MATH1} {<NR3>|ECL|TTL }
BUS:LOWerthreshold{:MATH|:MA
TH1}?
Related Commands
BUS:UPPerthreshold{:MATH|:MATH1}
Arguments
<NR3> is a floating point number that specifies the lower threshold for the
reference waveform, in volts.
ECL ECL (-1.3 volts). Note that this setting is constrained, depending upon the
vertical scale of the specified math waveform.
TTL TTL (1.4 volts). Note that this setting is constrained, depending upon the
vertical scale of the specified math waveform.
Examples
BUS:LOWerthreshold:MATH TTL sets the lower threshold for the math
waveform to 1.4 volts.
BUS:LOWerthreshold:MATH? might return 0.0E+0, which is the default.
BUS:LOWerthreshold:REF<x>
This command sets the lower threshold for each reference waveform. This applies
to all search and trigger types that use that reference waveform.
Group
Bus
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-205