Commands Listed in Alphabetical Order
PERCENT;ABSOL
UTE:HIGH 0 .0000;LOW 0.0000;MID1
0.0000;MID2 0.0000;:MEASUREMENT:REFLEVEL:PERCENT:HI GH
90.0000;LOW 10.0000;MID1 50.0000;MID2
50.0000;:MEASUREMENT:INDICATORS:STATE
OFF;NUMHORZ 0;NUMVERT 0;HORZ1 9 9.0000E +36;HORZ2
99.0000E+36;HORZ3 99.0000E+36;HORZ4 99.0000E+36;VERT1
99.0000E+3
6;VERT2 9 9.0000E+36;VERT3 99.0000E+36;VERT4
99.0000E+36;:MEASUREMENT:STATISTICS:MO DE OFF;WEIGHTING
32;:MEASUREMENT:GATING SCREEN
.
MEASUrem
ent:CLEARSNapshot (No Query Form)
Removes the measurement snapshot display.
Group
Measurement
Syntax
MEASUrement:CLEARSNapshot
Related Commands
CLEARMenu
MEASUrement:GATing
Specifies or returns the measurement gating setting.
Group
Measurement
Syntax
MEASUrement:GATing {OFF|SCREen|CURSor}
MEASUrement:GATing?
Arguments
OFF turns off measurement gating (full record).
SCREen turns on gating, using the left and right edges of the screen.
CURSor limits measurements to the portion of the waveform between the vert
ical
bar cursors, even if they are off screen.
Examples
MEASUREMENT:GATING CURSOR turns on measurement gating using the cursors
as limits.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-421