Commands Listed in Alphabetical Order
Returns
PASS, F AIL,orN
A
.
POWer:HARMonics:RESults:HAR<1-400>:TEST:IEC:POHCLIMit? (Query Only)
Specifies if the higher harmonic limit (and conditions) for the 21st and higher
order odd harmonics are m
et.
NOTE. The query returns NA if the limit does not apply for a specic harmonic.
Conditions
This command requires
a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:HARMonics:RESults:HAR<1-400>:TES T:IEC:POHCLIMit?
Returns
PASS, F AIL,orNA.
POWer:HARMonics:RESults:HAR<1-400>:TEST:MIL:NORMAL? (Q uery Only)
Returns the test result for the specified harmonic for the MIL-STD-1399 Section
300A testing standard.
This query is analogous to that for the IEC 61000-3-2 standard
POWer:HARMonics:RESults:HAR<1-400>:TEST:IEC:NORMAL? command.
NOTE. The query returns NA if the standard does n ot specify a limit for the
specic harmonic.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MD
O3000 series models.
Group
Power
Syntax
POWer:HARMonics:RESults:HAR<1-400>:TES T:MIL:NORMAL?
Returns
PASS, F AIL,orNA.