EasyManuals Logo

Tektronix MDO3000 Series Program Manual

Tektronix MDO3000 Series
1158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #520 background imageLoading...
Page #520 background image
Commands Listed in Alphabetical Order
POWer:QUALit
y:DISplay:FREQuency
This command specifies the display state for the frequency readout.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:QUALity:DISplay:FREQuency {OFF|ON|0|1}
POWer:QUALity:DISplay:FREQuency?
Arguments
OFF or 0 turns off the frequency display.
ON or 1 turns on the frequency display.
Examples
POWER:QUALITY:DISPLAY:FREQUENCY 1 turns on the frequency readout
display.
POWER:QUALITY:DISPLAY:FREQUENCY? might return
:POWER:QUALITY:DISPLAY:FREQUENCY 0 indicating that the
frequency readout display is off.
POWer:QUALity:DISplay:ICRESTfactor
This command specifies the display state for the current crest factor readout.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:QUALity:DISplay:ICRESTfactor {OFF|ON|0|1}
POWer:QUALity:DISplay:ICRESTfactor?
Arguments
OFF or 0 turns off the current crest factor display.
ON or 1 turns on the current crest factor display.
Examples
POWER:QUALITY:DISPLAY:ICRESTFACTOR 1 turns on the current crest factor
display.
2-490 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Table of Contents

Other manuals for Tektronix MDO3000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MDO3000 Series and is the answer not in the manual?

Tektronix MDO3000 Series Specifications

General IconGeneral
BrandTektronix
ModelMDO3000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals