Commands Listed in Alphabetical Order
Group
Power
Syntax
POWer:SOA:RESult:FAILures:QTY?
Examples
POWER:SOA:RESULT:FAILURES:QTY? might return
:POWER:SOA:RESULT:FAILURES 0 indicating that the number of failures is 0.
POWer:SOA:RESult:NUMACq? (Query Only)
Returns the number of acquisitions in the test.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:SOA:RESult:NUMACq?
Examples
POWER:S
OA:RESULT:NUMACQ?
might return :POWER:SOA:RESULT:NUMACQ
10
indicating that the number of acquisitions is 10.
POWer:SOA:RESult:STATE? (Query Only)
Returns the pass/fail state of the SOA test.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:SOA:RESult:STATE?
Returns
PASS or FAIL.
Examples
POWER:SOA:RESULT:STATE? might return :POWER:SOA:MA SK:STATE PASS
indicating that the SOA test state is PASS.
2-516 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual