Commands Listed in Alphabetical Order
SEARCH<x> is th
esearchnumber,whichisalways1,and
B<x> is the bus number
B1–B4, except for MDO3000, which has two buses B1–B2.
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FL EXray:CONDition
{SOF|FRAMETypeid|CYCLEcount|HEADer|DAT A|IDANDDATA|EOF|ERROR}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FL EXray:CONDition?
Arguments
SOF sets the search condition to start of frame.
FRAMETypeid sets the search condition to a frame type id.
CYCLEcount sets the search condition to cycle count.
HEADer sets the search condition to header.
DATA sets the search condition to data.
IDANDDATA sets the search condition to ID and data.
EOF sets the search condition to EOF.
ERROR sets the search condition to an error.
Examples
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRA Y:CONDITION ERROR sets
the FlexRay condition to ERROR
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRA Y:CONDITION? might
return
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY :CONDITION SOF
indicating the FlexRay condition is start of frame.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue
This command specifies the upper data value of the range to be
used when searching on the FlexRay bus cycle count field. (Use
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue
to set the low value.) The search condition must be set to CYCLEcount
(using SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:CONDition).
SEARCH<x> is the search number, which is always 1, and B<x>
2-648 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual