Commands Listed in Alphabetical Order
Arguments
LESSthan sets t
he LIN data qualifier to less than.
MOREthan sets the LIN data qualifier to greater than.
EQual sets the LIN data qualifier to equal.
UNEQual sets the LIN data qualifier to not equal.
LESSEQual sets the LIN data qualifier to less than or equal.
MOREEQual sets the LIN data qualifier to greater than or equal.
INrange sets the LIN data qualifier to in range.
OUTrange s
ets the LIN data qualifier to out of range.
Examples
TRIGGER:A:BUS:B1:LIN:DATA:QUALIFIER OUTRANGE sets the data qualifier
to out of range.
TRIGGER:A:BUS:B1:LIN:DATA:QUALIFIER? might return
TRIGGER:A:BUS:B1:LIN:DATA:QUALIFIER EQUAL indicating the data
qualifier is set to equal.
TRIGger:A:BUS:B<x>:LIN:DATa:SIZe
This command specifies the length of the data string in bytes to be used for LIN
trigger.
B<x>
Conditions
This command requires a DPO4AUTO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AUTO application module for
MDO3000 models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:LIN:DATa:SIZe <NR1>
TRIGger:A:BUS:B<x>:LIN:DATa:SIZe?
Argu
ments
<NR1> is the size of the data string in bytes.
Examples
TRIGGER:A:BUS:B1:LIN:DATA:SIZE 8 sets the data size to 8 bytes.
TRIGGER:A:BUS:B1:LIN:DATA:SIZE? might return
TRIGGER:A:BUS:B1:LIN:DATA:SIZE 1 indicating the data size is 1 byte.
2-828 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual