Commands Listed in Alphabetical Order
Conditions
This command re
quires the DPO4USB application module to be installed, except
for MDO3000 models, which require the MDO3USB. Note that 1 GHz bandwidth
models are recommended for high-speed (HS) USB.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:USB:ERRTYPE {PID|CRC5|CRC16| BITSTUFFing}
TRIGger:A:BUS:B<x>:USB:ERRTYPE?
Related Commands
TRIGger:A:BUS:B<x>:USB:CONDition
Arguments
PID indicates the error type is set to packet ID.
CRC5 indicates the error type is set to 5-bit CRC.
CRC16 indicates the error type is set to 16-bit CRC.
BITSTUFFing indicates the error type is set to bit stuffing.
Examples
TRIGGER:A:BUS:B1:USB:ERRTYPE PID sets the error trigger condition to
packet ID.
TRIGGER:A:BUS:B1:USB:ERRTYPE? might return
:TRIGGER:A:BUS:B1:USB:TYPE PID, indicating th
e error trigger condition is
packet ID.
TRIGger:A:BUS:B<x>:USB:HANDSHAKEType
This command specifies the handshaketypefortheUSBtrigger.B<x>
Conditions
This command requires th
e DPO4USB application module to be installed, except
for MDO3000 models, which require the MDO3USB. Note that 1 GHz bandwidth
models are recommended for high-speed (HS) USB.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:USB:HANDSHAKEType {ANY|NAK|ACK|S TALL}
TRIGger:A:BUS:B<x>:USB:HANDSHAKEType?
Related Commands
TRIGger:A:BUS:B<x>:USB:CONDition
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-865