Horizontal and acquisition setups Autoset
The following table lists the A utoset default settings.
Control Changed by Autoset to
Selected Channel
Last channel selected
Acquisition Mode
Sample
Run/Stop
Run
Deskew, Channel/Probe
Unchanged
Display S tyle
Vectors
Display Intensity–Record View
If less than 50%, set to 75%
Display Format YT
Horizont
al Position
Centered within the g raticule window
Graticule Setting
Unchang
ed
Horizontal Scale As determined by the signal frequency, or 100 µs/div
Record Length and Sample Rate
When a n
ew time per division is calculated, the sample rate
changes to maintain the current record length. If the s ample
rate cannot be changed because of hardware limitations,
the sa
mple rate is set to maximum while the record length is
reduced to maintain the time per division.
Trigg
er Position
Delay Off
Trigger A >B Sequence A Only
Main
Trigger Type
Edge
Tri
gger Source
Num
erically lowest displayed channel (the selected channel)
Trigger Level
50%
of selected channel amplitude
Tr
igger Slope
Positive
T
rigger Coupling
D
C
T
rigger Holdoff
Minimum setting
Vertical Scale
As determined by the signal level
Vertical Position
As determined by the number of active channels
Vertical Coupling DC unless AC was previously set. A C remains unchanged.
Vertical Bandwidth Full
Vertical Offset
0volts
Zoom
Off
xxx
184 DSA/DPO70000D, MSO/DPO/DSA70000C, DPO7000C, and MSO/DPO5000 Series