Command Descriptions
TDS Family Oscilloscope Programmer Manual
2–321
POSITIVe specifies a positive pulse.
TRIGger:MAIn:PULse:WIDth:WHEn
TDS 510A, 500C, 600B, & 700C Only
Selects the condition when the trigger occurs. This is equivalent to selecting the
condition in the Pulse Width Trig When side menu.
Trigger
TRIGger:MAIn:PULse:WIDth:WHEn { OUTside | WIThin }
TRIGger:MAIn:PULse:WIDth:WHEn?
<Space>
?
TRIGger :
:
OUTside
WIThin
PULse
MAIn
WIDth :
WHEn
:
OUTside specifies a trigger when the duration of the pulse is greater than the
high limit or less than the low limit specified. The high and low limits are
specified with the TRIGger:MAIn:PULse:WIDth:HIGHLimit and
TRIGger:MAIn:PULse:WIDth:LOWLimit commands respectively.
WIThin specifies a trigger when the duration of the pulse is within the high and
low limits. The high and low limits are specified with the
TRIGger:MAIn:PULse:WIDth:HIGHLimit and
TRIGger:MAIn:PULse:WIDth:LOWLimit commands respectively.
TRIGGER:MAIN:PULSE:WIDTH:WHEN?
returns either OUTSIDE or WITHIN, indicating the conditions for generating a
pulse trigger.
TRIGger:MAIn:TYPe
Sets or queries the type of main trigger. This is equivalent to setting Type in the