Temperature Sense Board
To remove the temperature sense board complete the following steps:
1. Remove the mainframe cover by following the Mainframe Cover removal
procedure on page 22.
2. Disconnect the ribbon cable from the temperature sense board.
3. Refer to Figure 16 and gently pry back on each retainer holding the
temperature sense board in place.
4. Tilt the board forward and lift it out of the holes at the top of the mainframe
being careful not to damage any components on the circuit board.
Complete the following steps to install the temperature sense board in the
mainframe:
1. Refer to Figure 16 and install the temperature sense board in the mainframe
as shown.
2. Make sure that the circuit board snaps into place under each retainer.
3. Reconnect the ribbon cable.
4. Reinstall the mainframe cover.