82 www.behnke-online.de
GB
Instructions SIP intercoms series 20-0001BS, 20-0014BS, 20-0016BS
Commissioning and configuration
Activation time of relay 2 Default: 5
13 1 # 1 second
: :
90 # 90 seconds
This configuration step is used to set the activation time for operation as a door opener relay
(operating modes 1 to 6) or the activation duration of an additional bell at the beginning of a direct
call (operating mode 10).
Activations codes for relay 2
14 1. Activation code #
15 2. Activation code #
Activation codes consist of digits only and may be up to eight digits long.
In the delivery state, no activation codes are specified for relay 2.
The following special symbols are allowed at the start when entering activation codes:
*1 = Activation code applies to indoor intercom station
*2 = Activation code applies to code lock
If no special symbol is entered, the activation code applies to the last setting made.
Operating mode keypad Default: 7
16 0 # deactivated
1 # Phone
2 # Code lock
3 # Speed dial
4 # Phone & code lock
5 # Phone & speed dial
6 # Code lock & speed dial
7 # Phone & code lock & speed dial
If the device has a physical keypad, it can be used to provide various functions. The keypad has
function keys (handset key, key button, i key, + key) that allow to call the corresponding function.
Here you can define which function or which combination of functions of the keypad should be
allowed. The following functions are available: