87www.behnke-online.de
GB
Instructions SIP intercoms series 20-0001BS, 20-0014BS, 20-0016BS
Commissioning and configuration
Analogue phone
Operating mode, if the device is connected to an analogue phone line
SIP phone
Operating mode, if the device is connected to a SIP server (IP phone system) as a SIP subscriber
or if the device is supposed to communicate directly with other SIP phones (SIP direct calls)
IP intercom station
Operating mode, if the device is operated while connected with further devices as
IP intercom station
Reset administrator password for web interface Default: admin
73 * * * * #
If the administrator password for configuring the device via the web interface was forgotten, it can
be reset to the default value via this configuration step.
Subsequently, you can log on to the web interface with the given administrator password.
Network connection Default: 0
74 0 # Wired Ethernet
1 # VLAN
2 # VLAN for webcam only
3 # VLANs for device and webcam
4 # WiFi
Here you can set how the device is connected to the IP network.
Normally, the device is connected to the Ethernet port of a PoE switch via network cable.
This supplies the device with power (Power over Ethernet) and connects it to the network.
Optionally, the device can also be connected to a wireless network (WiFi).
Wired Ethernet
Connection to a LAN or an untagged VLAN