Specifications
Connection
Call answering: automatically after 0-60 s, manually at the push of a button or reject
Incoming call
Connecting...: unlimited or 5 s - 5 min max.
separately adjustable for single calls and call chains
Connection time: unlimited or max. 1-9 min
Disconnection: adjustable: allowed, allowed after 1-30 s, not allowed
DTMF post-dialling: adjustable, if allowed or not (if key-dialling
block available)
Buttons
physical keys: compact intercom station: 1-2
modular intercom station: 1-8
Detached intercom station: 1 (via RJ45 socket) or with door module: 1-8 or 1-4 and keypad
via key extension modules: 25 per module, 75 max.
Display keys: small display: 10 max.
medium display: 30 max.
Activation duration: adjustable, minimum or 1-5 s (does not apply to display keys or keys of expansion
modules)
Debounce duration: 10-200ms
Features: Call, group call with 2-4 numbers (not with analogue phone), call chain with
2-4 numbers, call according to schedule, door open always or according to schedule,
output individual voice announcement Keypad if available
Features: Phone function, code lock function, speed dial function, direct call button i
Phone function: Dialling any phone number
Code lock function: Entering a code to control a relay with it
Speed dial function: Enter a 2-digit speed dial to call a stored number
Functions of the i key: Call, group call with 2-4 numbers (not with analogue phone), Call chain with 2-4
numbers, call according to schedule, door open always or according to schedule,
output individual voice announcement