96 www.behnke-online.de
GB
Instructions SIP intercoms series 20-0001BS, 20-0014BS, 20-0016BS
Specifications
Relay
Quantity: 2
Operating mode: Adjustable per relay: Door opener relay, connection indicator, additional bell or fault
indication
Switching voltage: 30 VDC / 30 VAC max.
Switching current: 2 A max.
Switching capacity: 60 W / 60 VA max.
Switching contact: when operating as a door opener relay: Normally open or normally
closed contact
Misc.: Normally open contact
Door opener relay: Control of a door opener for opening an access
Opening time: 1-90 s
Codes: 9 max., valid for in-house remote station or code lock, always or according to
schedule manual, permanent opening (can be activated via codes) or automatic
opening according to schedule possible
Activation via door opener button possible, always or according to
schedule Logging of access control by e-mail
Connection indicator: Control of the relay when the device is connected,can be activated for incoming
connection, outgoing connection or outgoing connection after the remote station
is answered
Additional bell: Triggering the relay during ringing on an incoming call, at the
beginning of a direct call (1-90 s) or during setup of a direct call
Fault indication: Control of the relay when a fault (network connection,
SIP registration) is present on the device
Card reader (if used)
Supported card readers: Behnke USB card reader
Operating mode: integrated or independent operation
Authorisation of cards: locally or via authorisation server
Operation as authorisation server possible
Authorisation profiles: max. 10 with max. 20 cards each
Features: Door opening, always or according to schedule
adjustable per authorisation group

Table of Contents