User Manual E3
59300623 Rev.001
5.4.2018 18(20)
RIS module
When E61 module is installed, the communication frequency and status is
shown with:
Scanning: Searching for RIS carrier.
Locked: Locked to RIS carrier, but no commands received in last 2
minutes. This usually means that this E61’s MAC address has not been
entered in RIS controller’s device list.
Connected: Locked to RIS carrier and receiving commands.
The Controller IP and Controller ID fields display the RIS controller (HDM155)
identification data received via RIS link. These are needed in networks
equipped with multiple RIS controllers for assigning the RIS receivers to correct
RIS controllers.
Alarms
Active alarms are listed in the bottom left corner and colour coded according to
severity. For additional information about alarms, see table of module alarm
descriptions in the "Alarms" chapter.
Measurements
The “TEMP” field displays E3’s internal temperature. It is typically 10…25
degrees above ambient temperature depending on installation.
The “AC” field is visible only with remote powered E3 model and shows the
measured RMS value of the remote supply voltage. This value is calculated
using sliding average and thus reacts quite slowly to changes.
The background colour of each field shows the parameter's alarm status.
Notes
The “Notes” field allows storing up to 200 character message into unit non-
volatile memory.