ME910C1 HW User Guide
1VV0301351 Rev.8 Page 44 of 99 2018-09-28
OPERATING LEVELS
Signal Status Min Max
HW_SHUTDOWN* Input high 1.5V 1.9V
HW_SHUTDOWN* Input low 0V 0.35V
WARNING:
The hardware unconditional Shutdown must not be used during
normal operation of the device since it does not detach the device
from the network. It shall be kept as an emergency exit procedure.
A typical circuit is the following: